A 2500mAh NiMH Battery

A 2500mAh NiMH Battery

A 2500mAh NiMH battery is a rechargeable nickel metal hydride cylindrical cell with 1.2V nominal voltage. It is designed for battery assemblies that require 2500mAh capacity, 50A cell dimensions, controlled charging, high discharge current capability, storage stability, and defined safety handling conditions.

  • Rated voltage: 1.2V
  • Cell model: GMCELL 50A2500mAh rechargeable NiMH cylindrical cell
  • Capacity: 2500mAh nominal capacity and 2500mAh minimum capacity
  • Standard charge: 250mA, 0.1C, 16 hours at 20±5℃
  • Quick charge: 1250mA, 0.5C, 2.4 hours at 10–40℃ with -ΔV=5mV/cell control
  • Dimensions: 17.0mm diameter × 50.0mm height with tube; approx. 37.0g per cell
  • Datasheet:

    Download PDF

For replacement or sourcing, confirm voltage, 50A cell dimensions, capacity, charging method, maximum discharge current, storage condition, polarity, terminal structure, and pack assembly requirements before ordering.

Description

A 2500mAh NiMH Battery Product Attributes

Key Features:

1. Rechargeable A-size Ni-MH cylindrical cell with 1.2V nominal voltage and 2500mAh nominal capacity.

2. Minimum capacity is 2500mAh under standard charge and discharge condition.

3. Standard charge is 250mA, 0.1C, for 16 hours at 20±5℃.

4. Quick charge supports 1250mA, 0.5C, for 2.4 hours at 10–40℃ with -ΔV=5mV/cell control.

5. Maximum discharge current is 7500mA, 3C, with 0.7V/cell cut-off.

6. Cell size with tube is 17.0mm diameter and 50.0mm height; approximate weight is 37.0g.

7. Recommended storage condition is -20℃ to 35℃, low humidity, and no corrosive gases.

Type Description
Category Ni-MH Batteries

Ni-MH Rechargeable Batteries

NiMH A Batterieies

Mfr GMCELL
Series GMCELL®
Part Status Active
Battery Chemistry Nickel Metal Hydride
Battery Type Rechargeable Nickel Metal Hydride Cylindrical Cell
Model GMCELL 50A2500mAh
Specification Ni-MH 50A2500mAh 1.2V
Battery Configuration Single A-size NiMH cell, 1 × 1.2V
Voltage – Rated 1.2 V
Nominal Capacity 2500mAh under standard charge / discharge condition
Minimum Capacity 2500mAh
Internal Resistance ≤30mΩ within 1 hour after standard charge
Open Circuit Voltage ≥1.25V within 1 hour after standard charge
Standard Charge 250mA, 0.1C, 16 hours at 20±5℃
Quick Charge 1250mA, 0.5C, 2.4 hours at 10–40℃, -ΔV=5mV/cell
Trickle Charge 0.02C–0.05C at 0–40℃
Standard Discharge 500mA, 0.2C discharge to 1.0V/cell at 20±5℃
Maximum Discharge Current 7500mA, 3C, with 0.7V/cell cut-off at -20℃ to 60℃
Low Rate Discharge ≥300 minutes at 0.2C after standard charge and 1 hour rest
High Rate Discharge ≥112 minutes at 0.5C; ≥51 minutes at 1C after standard charge and 1 hour rest
Charge Retention ≥1500mAh, 60%, after 28 days at ambient temperature or 7 days at 45℃
IEC Cycle Life Test ≥300 cycles according to IEC 61951-2:2017 / 7.5.1.2
Operating Temperature Standard charge: 20±5℃; fast charge: 10–40℃; discharge: -20–60℃
Storage Temperature Within 1 year: -20℃ to 25℃; within 6 months: -20℃ to 35℃; within 1 month: -20℃ to 45℃; within 1 week: -20℃ to 55℃
Storage Recommendation Store under -20℃ to 35℃, low humidity, and no corrosive gases; 1–3 charge/discharge cycles may be needed after long-term storage
Dimensions Diameter 17.0mm (+0/-0.7); height 50.0mm (+0/-1.0); top diameter 8.0mm; top height 0.6mm
Weight Approx. 37.0g per cell
Overcharge Test 0.1C charge for 48 hours; no leakage or deformation required
Short Circuit Test Leakage and deformation may occur, but no explosion is allowed after standard charge short-circuit test
Vibration Resistance Voltage change <0.02V/cell and internal resistance change <5mΩ/cell after vibration test
Impact Resistance Voltage change <0.02V/cell and internal resistance change <5mΩ/cell after three 100cm drop tests
Leakage Test No leakage or deformation after 14 days storage following standard charge
Safety Test No disrupt, burst, or explosion after forced discharge test; electrolyte leakage and deformation are acceptable
Warranty One-year limited warranty against workmanship and material defects
Electricity Retains Before Delivery Normally not less than 50% before delivery unless otherwise confirmed by special requirement
Charging Method Use the correct charger for Ni-MH batteries; do not reverse charge, short circuit, or solder directly to the cell
Replacement Checkpoints Confirm voltage, capacity, 50A cell dimensions, charge method, discharge current, storage condition, polarity, and pack assembly requirements before ordering
Shipping Info Store batteries in a cool dry place; discharge batteries before bulk storage or shipment