89F 14000mAh NiMH Battery

89F 14000mAh NiMH Battery

89F 14000mAh NiMH battery is a rechargeable cylindrical sealed nickel metal hydride cell with 1.2V nominal voltage. It is designed for battery packs and electronic equipment that require 14000mAh nominal capacity, controlled charging, stable discharge performance, defined storage conditions, and safety testing according to the supplied specification.

  • Rated voltage: 1.2V
  • Cell model: GMCELL-89F14000mAh rechargeable NiMH cylindrical cell
  • Capacity: 14000mAh nominal capacity and 13700mAh minimum capacity at 0.2C
  • Standard charge: 1400mA × 14 hours
  • Rapid charge: 2800mA × 390 minutes with -ΔV=5mV/pcs control
  • Dimensions: D 32.0–32.5mm × H 87.5–90.0mm; approx. 244g per cell
  • Datasheet:

    Download PDF

For replacement or sourcing, confirm voltage, 89F cell dimensions, nominal capacity, minimum capacity, charging method, discharge temperature range, storage condition, polarity, terminal structure, and pack assembly requirements before ordering.

Description

89F 14000mAh NiMH Battery Product Attributes

Key Features:

1. Rechargeable cylindrical sealed nickel metal hydride battery with 1.2V nominal voltage and 14000mAh nominal capacity.

2. Minimum capacity is 13700mAh when tested at 0.2C discharge to 1.0V.

3. Standard charge rate is 1400mA for 14 hours.

4. Rapid charge rate is 2800mA for 390 minutes with -ΔV=5mV/pcs control.

5. Cell dimensions are D 32.0–32.5mm and H 87.5–90.0mm.

6. Internal impedance is specified as no more than 15mΩ after standard charge.

7. Cycle life exceeds 500 charge-discharge cycles under IEC61951-2:2017 test conditions.

Type Description
Category Ni-MH Batteries

Ni-MH Rechargeable Batteries

Other Types NiMH Batteries

Battery Chemistry Nickel Metal Hydride
Battery Type Cylindrical Sealed Nickel Metal Hydride Battery
Model GMCELL-89F14000mAh
Customer P/N 2060098
Issued Date 2021-11-15
Voltage – Rated 1.2 V
Nominal Capacity 14000mAh
Minimum Capacity 13700mAh / 0.2C
Standard Charge 1400mA × 14hrs
Rapid Charge 2800mA × 390min, -ΔV=5mV/pcs
Charge Voltage Less than 1.6V before the end of standard charge
Open Circuit Voltage Greater than 1.25V within 1 hour after standard charge
Closed Circuit Voltage Greater than 1.2V with 0.86Ω load within 1 hour after standard charge
Internal Impedance ≤15mΩ at 1000Hz within 1 hour after standard charge
Capacity Test Discharge at 0.2C mA to 1.0V after standard charge and 1 hour rest; capacity shall be greater than or equal to minimum capacity
High Drain Discharge 0.2C discharge to 1.0V within 1 hour after standard charge; discharge time ≥295 minutes
Self Discharge Remaining capacity ≥70% of rated capacity after 28 days storage below 20℃
Cycle Life More than 500 cycles according to IEC61951-2:2017
Standard Charge Temperature 0–40℃ / 32–104℉
Rapid Charge Temperature 10–35℃ / 50–95℉
Floating Charge Temperature -10–40℃ / 14–104℉
Discharge Temperature -20–55℃ / -4–131℉
Operating Humidity 65% ±20%
Storage Within 1 Year -20–35℃ / -4–95℉
Storage Within 6 Months -20–45℃ / -4–113℉
Storage Within 1 Month -20–50℃ / -4–122℉
Recommended Storage Condition Store at -20℃ to +35℃, preferably 15℃ to 25℃, in a clean, dry, ventilated place with relative humidity 85% max.
Dimensions D 32.0–32.5mm; H 87.5–90.0mm; D1 10.0±0.2mm; H1 0.8±0.3mm
Weight Approx. 244g
Insulation Resistance Outer sleeve shall exceed 10MΩ
Overcharge Test After standard charge, charge at 0.1C mA for 48hrs; no external deformation or leakage, and capacity shall be greater than or equal to rated capacity
Over-discharge Test After 0.2C discharge to 1.0V and 24hrs with 0.86Ω load, capacity shall be no less than 80% of rated capacity after standard charge
Humidity Test Standard charge, then store 14 days at 33±3℃ and 80±5% relative humidity; no liquid electrolyte leakage
Vibration Resistance Amplitude 4mm, frequency 1000 cycles/min, continuous 60min in any direction; OCV fluctuation <0.02V and internal impedance change <5mΩ
Drop Test Drop from 450mm onto hardwood board; OCV fluctuation <0.02V and internal impedance change <5mΩ
Short Circuit Test 1 hour short-circuit test after standard charge; battery shall not explode, while leakage, deformation, or outer sleeve cracking is permitted
Safety Valve Performance – Over-discharge Discharge at 0.2C to 0V, then raise the current to 0.5C and discharge for 60min; safety valve must start normally and battery shall not break
Safety Valve Performance – Overcharge Charge at 0.5C mA for 5 hours; no explosion, while leakage, distortion, and outer package breakage are allowed
Low Temperature Discharge After standard charge and 24hrs storage at 0℃±2℃, discharge at 0.2C mA at 0℃±2℃; discharge duration shall exceed 3 hours 30 minutes
Delivery Charge Battery charge before delivery is specified as less than 50% fully charged
Storage Charge Note Batch batteries should be stored with 50% electric charge; if storage exceeds 3 months, discharge at 0.2C to 1.0V and then add 50% electricity for storage
Warranty 12 months
Transportation Keep clean, dry, and well ventilated during transportation; prevent fierce vibration, impact, extrusion, sun exposure, and rain
Storage Placement Packed cartons should be stacked less than 5 layers, with 5–10cm or more spacing between cartons for air circulation
Charging Method Use the charger appointed by GMCELL for Ni-MH batteries; all rapid charge methods should be discussed with GMCELL engineers
Safety Notes Do not throw into fire, heat, collide, disassemble, short circuit, overcharge, reverse charge, or weld leads directly on the battery